Fig. 2 MODEL 302-ET AP-P THERMOTECH 2900 N. 1000 W.
The detector consists of a high expansion aluminum tube which encases two insulation struts with opposing open constant points (see cut-away view). is not as much time for heat to penetrate the inner strut. The rapid ... Doc Retrieval
Fire Alarm Control Panels MS-5UD Series MS-10UD Series
B1 P/N 52626:B1 ECN 09-432 Document 52626 6/30/2009 Rev: Fire Alarm Control Panels MS-5UD Series MS-10UD Series Manual ... Read Document
Phase Out Announcement Of PE / DT / 8800-Series Conventional ...
Phase Out Announcement of PE / DT / 8800-Series Conventional Detectors OH121 S54372-F2-A1 Conv. Optical/Heat combined 6192 PE-11T, PE-11TC, HI121-Conventional-Detection-Devices--Thermal-Heat-Detector-Data-Sheet_A6V10338994_us-en.pdf PE-Series Catalog Sheet ... Doc Retrieval
IntelliKnight Model 5820XL Addressable Fire Alarm - Silent Knight
IntelliKnight® Model 5820XL Addressable Fire Alarm Control System INTELLIKNIGHT FIRE ALARM CONTROL PANEL detector • Addressable detector • Addressable heat sensor • Addressable duct smoke detector ... View This Document
MS-9200UDLS(E) Rev 3 - PROtech Security & Electronics
MS-9200UDLS(E) Rev 3 Intelligent Addressable FACP puter (cable not included), available on www.firelite.com. DP-9692: Optional dress panel for MS-9200UDLS Rev 3. TR-CE: H355: Fast-response, low-profile heat detector. H355R: Fast-response, low-profile heat detector with rate-of-rise option. ... Fetch This Document
SD505-AHS Addressable Heat Detector - Silent Knight
Model SD505-AHS Addressable Heat Detector The SD505-AHS is a heat detector suited to virtually any commercial setting. The SD505-AHS is an absolute temperature device. ... Read Content
P.1.18.01 Photoelectric Smoke Detector
The 63-1024 Photoelectric Smoke Detector has a built-in automatic sensitivity test feature. 1. In normal condition, The base shall permit direct interchange with Fike 63-1025 combination photoelectric/heat detector, 67-1033 ionization ... Fetch Content
Addressable Fire Alarm Control Panel MS-9200UDLS MS-9200UDLSE ...
Addressable Fire Alarm Control Panel MS-9200UDLS MS-9200UDLSE detectors, heat detectors, manual pull stations, audible warning devices, and a fire alarm control panel necessarily best and a given type of detector may not provide ... View Document
Wireless Smoke/Heat Detectors - Library.ademconet.com
Wireless Smoke/Heat Detectors The Ultimate Protection † Heat detector combines both rate-of-rise and fixed temperature sensors in one unit Honeywell’s wireless smoke and heat detectors are monitored by the central station 24 hours, ... Read Document
FIRE ALARM DEVICE LEGEND - Maitland, Florida
Fire alarm device legend description addressable smoke detector firelite sd355 mounts to existing box as per drawing addressable heat detector firelite hd355 mounts to existing box as per drawing ... View This Document
Ont: Sensor Documents - YouTube
Skip navigation Sign in. Search ... View Video
Fire Alarm Control Panel - Wikipedia
Addressable Fire Alarm Control Panel employ one or more Signaling Line Circuits Heat Detectors The prealarm LED may also be used if an addressable smoke detector registers low levels of smoke in the detection chamber, ... Read Article
The MS-4412B/MS-4424B(E) FIRE ALARM CONTROL PANELS
The MS-4412B/MS-4424B(E) FIRE ALARM CONTROL PANELS DOCUMENT 15125 ECN 97-192 heat detectors, manual pull stations, audible warning devices, and a fire alarm control floor detector, for example, may not sense a first floor or basement fire. Further- ... Access Document
Fast Pull Reset--edwards 270 Spo Pull Station - YouTube
Skip navigation Sign in. Search ... View Video
MS-9050UD - CSSGA
The MS-9050UD’s integral DACT transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the H355: Fast-response, low-profile heat detector. H355R: Fast-response, low-profile heat detector with rate-of-rise option. ... View Full Source
302 Series - Harrington Fire
Heat Detector, 194 Deg., Vertical Mt., Hex Bushing, All-Weather (may mount horizontal) Heat Detector, 135 Deg., Vertical Mt., All-Weather Heat Detector, 194 Deg., Vertical Mt., All-Weather Heat Detector, 135 Deg., Explosion-proof ... View Document
CNM Fire Alarm Systems And Devices
CNM Fire Alarm Systems and Devices Horn Duct Door Elevator Campus Building Name Fire Panel Type Proprietory Panel Location Address Zip Code Contractor Pulls Bells Strobe Smoke Heat Detector Holder Recall Main Firelite South Hallway By Stairs 1506 Candelaria NE 87107 41 ... View Document
MS-25(E)(C) - SES - Online
The Fire†Lite MS-25(E)(C) is a Fire Alarm Control Panel (FACP) and Digital Alarm Communicator/Transmitter ture heat detector. Includes base. HFS-MM: www.firelite.com Made in the U.S. A. System Capacity ... Read Here
INSTALLATION AND MAINTENANCE INSTRUCTIONS 5600 Series Heat ...
INSTALLATION AND MAINTENANCE INSTRUCTIONS WARNING 5600 Series Heat Detector Single Circuit: 5601A, 5602A, 5603A, 5604A Dual Circuit: 5621A, 5622A, 5623A, 5624A Table 1. 5600 Series Heat Detectors Figure 1. Bracket Mounting Locations ... Get Doc
Smoke, Heat, And Duct Detectors Application Bulletin
Overview of smoke, heat, and duct detectors 2 Smoke, Heat, and Duct Detectors Application Bulletin Duct smoke detector applications section of this document lists the applications ... Get Doc
GENERAL
Www.firelite.com Section: Addressable GENERAL with heat, ionization, photoelectric duct, fixed heat, cluding the new addressable dual-monitor module, heat detectors, and duct detector. • SLC loop maximum length 10,000 ft. (3,048 m) @ 12 AWG ... Access This Document
Consultant’s Guide For Designing Fire Detection & Alarm Systems
Consultant’s Guide for Designing Fire Detection & Alarm Systems. contents guide to design of fire systems part one Purpose Detector zones and alarm zones Heat detectors Heat-enhanced Carbon monoxide fire detectors ... View This Document
No comments: